How to Use RECs in GRI Reporting
Market Insights | Feb/26/2026
Last updated: March 8, 2026
Renewable Energy Certificates (RECs) can support sustainability reporting by documenting the renewable attributes associated with electricity generation. In GRI reporting, their relevance depends on the organization’s reporting period, applicable GRI standards, and how it calculates energy use and emissions.
This guide explains where RECs fit in energy and Scope 2 disclosures, what information organizations should keep, and how the updated GRI standards address contractual instruments such as RECs and other Energy Attribute Certificates (EACs).
Where Do RECs Fit in GRI Reporting?
For reports using the GRI standards in effect before 2027, energy consumption and greenhouse gas emissions are addressed primarily through GRI 302: Energy 2016 and GRI 305: Emissions 2016. RECs may be relevant to the renewable electricity breakdown and to market-based Scope 2 calculations when they meet the applicable accounting criteria.
The location-based method uses average grid emissions data. The market-based method uses contractual instruments and other eligible supplier-specific information to reflect the electricity an organization has chosen to purchase. These results should be reported as separate figures where both methods apply.
Organizations reporting in accordance with GRI should also consider materiality and the relevant disclosure requirements. GRI reporting does not mean every organization must report every energy or emissions disclosure.
What Changes Under GRI 103 and GRI 102?
GRI 103: Energy 2025 and GRI 102: Climate Change 2025 are effective for reports and other materials published on or after January 1, 2027. Earlier adoption is encouraged. Until then, organizations should use the standards applicable to their reporting period and note which version they follow.
GRI 103: Energy 2025 adds specific disclosures about purchased electricity and contractual instruments. Where energy is a material topic, organizations reporting in accordance with GRI report the relevant disclosures, including whether instruments such as RECs are used and how they meet applicable quality criteria.
The standard also calls for purchased electricity to be broken down by renewable and non-renewable sources. Where applicable, organizations should report the type of contractual instrument used, along with the amount and percentage of purchased electricity it covers.
GRI 102: Climate Change 2025 addresses Scope 2 emissions. Disclosure 102-6 calls for gross location-based and, where applicable, market-based Scope 2 emissions, along with information on the methods and factors used in the calculation.
What Information Should Companies Keep?
Clear records help organizations connect their electricity data with the instruments used to report renewable attributes. For each reporting period, companies should be able to trace the electricity volume, certificate volume, market, and time period covered.
- Electricity data: Record purchased electricity consumption and the reporting period, with a breakdown by facility or country where useful.
- Instrument details: Record the type of instrument, volume, generation period, and market it applies to.
- Attribute ownership: Keep evidence that the renewable attributes are uniquely assigned and that certificates were redeemed, retired, or canceled by or on behalf of the reporting organization.
- Accounting method: State whether renewable electricity figures use grid-average data or contractual instruments, and document the standards, assumptions, and emission factors used.
GRI 103 guidance also identifies additional context that can help readers understand a purchase, such as the generation facility’s commissioning date, contract length, and whether the facility received government support.
How Are RECs Reflected in Scope 2 Reporting?
When an organization uses eligible RECs for market-based accounting, the certificates may inform the emission factor applied to the matched electricity consumption. Their use does not change the grid-average data used for a location-based calculation.
GRI 103’s guidance builds on the GHG Protocol Scope 2 Quality Criteria. It calls for instruments to convey the relevant emissions attribute, be tracked and retired or canceled, correspond as closely as possible to the consumption period, and come from the same market to which they are applied.
Organizations should describe how they apply these criteria and keep the market-based result distinct from the location-based result. A REC purchase should not be presented as a reduction in the organization’s physical electricity consumption.
How CnerG Supports REC Sourcing
At CnerG, we support organizations sourcing RECs and other EACs across markets. Our team can discuss available instruments and the transaction information buyers may need when organizing their electricity procurement records.
The reporting organization remains responsible for applying the relevant GRI disclosures and accounting criteria. Contact CnerG to discuss REC sourcing for your markets and reporting needs.
Summary
Where Do RECs Fit in GRI Reporting?
What Changes Under GRI 103 and GRI 102?
What Information Should Companies Keep?
How Are RECs Reflected in Scope 2 Reporting?
How CnerG Supports REC Sourcing
Related Content
Kiểm Soát Hoạt Động Phát Thải Của Bạn Ngay Hôm Nay!
Kiểm soát hoạt động phát thải và chiến lược phát triển bền vững của bạn